Qualifying the Fixturlaser Level When Using a Fixture

The Fixturlaser level is calibrated to earth level out of the box. If the level is used without a fixture it reads level directly. If a fixture is used, however, you must first qualify the level with the fixture. This is a very simple procedure when using the Fixturlaser NXA. Level measured with no fixture…

Read More

The Fixturlaser Level

The Fixturlaser Level is a two-axis level sensor that can be used wherever precision level measurements are required. It can be used to level machine bases or beds, bearings and journals, or for measuring “twist” on linear guide ways. The accuracy is very precise with resolution down to 0.01 mm/m (.1mil/1”) with a range of…

Read More

Long Distance Rough Alignment with the Coning Method

Recently, VibrAlign was called to consult with a customer to recommend a procedure and alignment tools for a very long-distance vertical pump alignment.  First, we will describe the machine and then how we aligned it.  This large raw sewage pump machine train begins at the driver level.  In this plant, floor levels are described by…